The Permanent Link covers the horizontal installation which includes the installation cable, patch panel, and the outlet or
junction box at the other end. The Channel Link covers the patch cords as well as the components of permanent link. A set
of measurements is dened in the ISO/IEC standard to unify the quality of structured cabling.
• Return Loss (RL)
The Return Loss is the measurement of the amount of signal that is reected back toward the transmitter. The reection
of the signal is caused by the variations of impedance in the connectors and cable and is usually attributed to a poorly
terminated wire. The greater the variation in impedance, the greater the return loss reading is.
• Attenuation-to-Crosstalk Ratio (ACR)
Attenuation-to-Crosstalk ratio (ACR) is the difference between the signal attenuation produced and NEXT. The ACR indicates
how much stronger the attenuated signal is than the crosstalk at the destination (receiving) end of a communications circuit.
• Power Sum ACR (PSACR)
The difference from the ACR is PSACR used PSNEXT in the calculation rather than NEXT.
• Near-End Cross Talk (NEXT)
It is the difference in amplitude (in dB) between a transmitted signal and the crosstalk received on other cable pairs at the
same end of the cabling. Higher NEXT values correspond to better cabling performance.
• Power Sum NEXT (PSNEXT)
Power Sum NEXT (PSNEXT) is the sum of NEXT values from 3 wire pairs as they affect the other wire pair.
• Far-End Crosstalk (ELFEXT)
FEXT is very similar to NEXT, but happens at the receiver side of the connection.
• Equal Level Far End Crosstalk (ELFEXT)
Equal Level Far End Crosstalk (ELFEXT) is a length-independent value for the transmission quality, which denes the ratio
of the crosstalk output level to the actual output level. The second pair of wires strewn on the noise level is compared to the
starting level.
• Power Sum ELFEXT (PSELFEXT)
Power Sum ELFEXT (PSELFEXT) is the sum of ELFEXT values from 3 wire pairs as they affect the other wire pair.
F/UTP
XX/XTP
Over all Shielding: F = Foil Shielded
S = Braiding
SF = Foil Shielding and Braiding
TP: Twisted Pair
Pair Shielding: U = Unshielded
F = Foil Shielded
cable without any shielding
cables with over all braiding and pairs
in metal foil (PIMF)
cable with over all foil shielding
cable with over all foil shielding and
braiding
SF/UTP
S/FTP
U/UTP
The Construction of Cable